CVE-2025-21895None▾ SunlitIn the Linux kernel, the following vulnerability has been resolved: perf/core: Order the PMU list to fix warning about unordered pmu_ctx_list Syskaller triggers a warning due to prev_epc->pmu != next_epc->pmu in perf_event_swap_task_ct…
▾ Sunlit zone — Low / medium · no exploitation signal
impact 2.8 · likelihood 0 · exploitation 0
Need a working PoC? Pro members can cast a request and our team develops one — it lands right here.
Stakeholder-Specific Vulnerability Categorization from CISA's ADP record at CVE.org: whether exploitation is observed, whether an attack can be automated, and how much of the system is at stake.
Exploit-prediction probability, daily snapshots since Nov 5.
Disclosure to exploitation, from the record and what we observed since indexing it.
Disclosed via CVEORG
Last analysed / modified upstream
0.1%
In the Linux kernel, the following vulnerability has been resolved:
perf/core: Order the PMU list to fix warning about unordered pmu_ctx_list
Syskaller triggers a warning due to prev_epc->pmu != next_epc->pmu in perf_event_swap_task_ctx_data(). vmcore shows that two lists have the same perf_event_pmu_context, but not in the same order.
The problem is that the order of pmu_ctx_list for the parent is impacted by the time when an event/PMU is added. While the order for a child is impacted by the event order in the pinned_groups and flexible_groups. So the order of pmu_ctx_list in the parent and child may be different.
To fix this problem, insert the perf_event_pmu_context to its proper place after iteration of the pmu_ctx_list.
The follow testcase can trigger above warning:
test.c
void main() { int count = 0; pid_t pid;
printf("%d running\n", getpid());
sleep(30);
printf("running\n");
pid = fork();
if (pid == -1) {
printf("fork error\n");
return;
}
if (pid == 0) {
while (1) {
count++;
}
} else {
while (1) {
count++;
}
}
}
The testcase first opens an LBR event, so it will allocate task_ctx_data, and then open tracepoint and software events, so the parent context will have 3 different perf_event_pmu_contexts. On inheritance, child ctx will insert the perf_event_pmu_context in another order and the warning will trigger.
[ mingo: Tidied up the changelog. ]
Linux >= bd27568117664b8b3e259721393df420ed51f57b < f0c3971405cef6892844016aa710121a02da3a23Linux >= bd27568117664b8b3e259721393df420ed51f57b < 7d582eb6e4e100959ba07083d7563453c8c2a343Linux >= bd27568117664b8b3e259721393df420ed51f57b < 3e812a70732d84b7873cea61a7f6349b9a9dcbf5Linux >= bd27568117664b8b3e259721393df420ed51f57b < 2016066c66192a99d9e0ebf433789c490a6785a2Linux 6.2Refer to the linked advisories for vendor-supplied fixes and affected version ranges.
Connected by shared product, vendor, weakness, or advisory.
CVE-2026-99284Nonenet: skbuff: propagate shared-frag marker in skb_zerocopy()
CVE-2026-99283Nonenetfilter: conntrack: tcp: use UNACK timeout for non-closing RST packets
CVE-2026-99272Nonesmb: client: validate the data area in SMB2_read()
CVE-2026-99271NoneALSA: line6: Clear prev_fbuf on capture buffer release
CVE-2026-99273Noneksmbd: reserve space for the UTF-16 terminator in stream info
CVE-2026-99275Nonesmb: client: reject short SESSION_SETUP responses