CVE-2025-60006Medium· 5.3▾ SunlitMultiple instances of an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the CLI of Juniper Networks Junos OS Evolved could be used to elevate privileges and/or execute unauth…
▾ Sunlit zone — Low / medium · no exploitation signal
impact 29.2 · likelihood 0.2 · exploitation 0
Need a working PoC? Pro members can cast a request and our team develops one — it lands right here.
Exploit-prediction probability, daily snapshots since Sep 30.
Disclosure to exploitation, from the record and what we observed since indexing it.
Disclosed via NVD
1.0%
Last analysed / modified upstream
Multiple instances of an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability in the CLI of Juniper Networks Junos OS Evolved could be used to elevate privileges and/or execute unauthorized commands.
When an attacker executes crafted CLI commands, the options are processed via a script in some cases. These scripts are not hardened so injected commands might be executed via the shell, which allows an attacker to perform operations, which they should not be able to do according to their assigned permissions.
This issue affects Junos OS Evolved:
This issue does not affect Junos OS Evolved versions earlier than 24.2R1-EVO.
junos_os_evolved = 24.2junos_os_evolved = 24.4Refer to the linked advisories for vendor-supplied fixes and affected version ranges.
Connected by shared product, vendor, weakness, or advisory.
CVE-2025-59967Medium· 6.5A NULL Pointer Dereference vulnerability in the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved on ACX7024, ACX7024X, ACX7100-32C, ACX7100-48L, ACX7348, ACX7509 devices allows an unauthenticated, adjacent attacke…
CVE-2025-52961Medium· 6.5An Uncontrolled Resource Consumption vulnerability in the Connectivity Fault Management (CFM) daemon and the Connectivity Fault Management Manager (cfmman) of Juniper Networks Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, …
CVE-2025-59958Medium· 6.5An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated, network-based attacker to cause impact to confident…
CVE-2025-59969Medium· 6.5A Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in the advanced forwarding toolkit (evo-aftmand/evo-pfemand) of Juniper Networks Junos OS Evolved on PTX Series or QFX5000 Series allows an unauthenti…
CVE-2026-33794Medium· 5.9An Improper Check for Unusual or Exceptional Conditions vulnerability in the advanced forwarding toolkit (evo-aftmand) of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated network-based attacker generating con…
CVE-2026-21915Medium· 6.7A Permissive List of Allowed Input vulnerability in the CLI of Juniper Networks Support Insights (JSI) Virtual Lightweight Collector (vLWC) allows a local, high privileged attacker to escalate their privileges to root. The CLI menu acce…