id: CVE-2026-58115
title: >-
  A vulnerability has been identified in SIMATIC IoT2050 Advanced
  (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with
  Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions
  < V4.3.4-1 running Ind…
summary: >-
  A vulnerability has been identified in SIMATIC IoT2050 Advanced
  (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with
  Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions
  < V4.3.4-1 running Ind…
severity: critical
cvss: 10
cvssVector: 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H'
cvssSource: cna
cwe:
  - CWE-306
vendor: Siemens
product: SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)
affected:
  - simatic_iot2050_advanced_6es7647-0ba00-1ya2 < V4.3.4-1
  - simatic_iot2050_basic_6es7647-0ba00-0ya2 < V4.3.4-1
  - simatic_iot2050_m.2_6es7647-0bb00-1ya2 < V4.3.4-1
  - simatic_iot2050_sm_6es7647-0ca00-1aa2 < V4.3.4-1
ssvc:
  exploitation: none
  automatable: 'yes'
  technicalImpact: total
  timestamp: '2026-08-12T17:59:33.476267Z'
exploitAvailable: true
published: '2026-08-11'
updated: '2026-11-04'
sourceUpdated: '2026-11-04T17:45:30.430Z'
source: CVEORG
sourceUrl: 'https://www.cve.org/CVERecord?id=CVE-2026-58115'
references:
  - url: 'https://cert-portal.siemens.com/productcert/html/ssa-834709.html'
tags:
  - cve.org
  - exploit-available
epss: 0.0089
epssPercentile: 0.59471
exploits:
  github: 2
  githubRepos:
    - 'https://github.com/foxcornlab/node-red-scanner'
    - 'https://github.com/al4n4n/CVE-2026-58115'
  checkedAt: '2026-11-05T21:36:37.191Z'
ingestedAt: '2026-11-05T21:36:00.469Z'
---

## Overview

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.
This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

## Affected

- `simatic_iot2050_advanced_6es7647-0ba00-1ya2 < V4.3.4-1`
- `simatic_iot2050_basic_6es7647-0ba00-0ya2 < V4.3.4-1`
- `simatic_iot2050_m.2_6es7647-0bb00-1ya2 < V4.3.4-1`
- `simatic_iot2050_sm_6es7647-0ca00-1aa2 < V4.3.4-1`

## Remediation

Refer to the linked advisories for vendor-supplied fixes and affected version ranges.