7 CVEsRSS
CVE-2026-39460High· 8.1Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file
Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the d…
CVE-2026-39453High· 8.3Navigating to a certain URL on the switch’s web server causes the switch to reboot
Navigating to a certain URL on the switch’s web server causes the switch to reboot. This can be automated using a tool like curl to create DoS conditions where the switch constantly reboots.
CVE-2026-33367High· 8.1SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication.
SNMP can be used to perform administrative actions such as retrieving configuration files, modifying user accounts or device settings, and initiating firmware or bootloader upgrades or downgrades—all without any authentication.
CVE-2026-33272Medium· 4.9A malicious user with physical access to the device can boot the switch from factory settings without authentication, use the default administrative credentials to obtain administrative access, and save changes to the configuration file …
A malicious user with physical access to the device can boot the switch from factory settings without authentication, use the default administrative credentials to obtain administrative access, and save changes to the configuration file …
CVE-2026-32645Medium· 6.0Default factory credentials with administrative access are enabled and persist even after configuring other administrator accounts.
Default factory credentials with administrative access are enabled and persist even after configuring other administrator accounts.
CVE-2026-29797High· 7.1No authentication is required when updating firmware or bootloader, making it easy for malicious files to be pushed to the device
No authentication is required when updating firmware or bootloader, making it easy for malicious files to be pushed to the device. Additionally, anyone with the same software can scan a network for N-Tron devices and push/pull firmware w…
CVE-2026-28745High· 7.5Usernames and passwords, including the default credentials, are stored in the configuration file using weak encryption
Usernames and passwords, including the default credentials, are stored in the configuration file using weak encryption. If the default credentials are known by a malicious user, they could obtain other credentials on the system.